simple_rotator_interface_v
Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| simple_rotator_interface_v [2026/05/26 10:40] – [DC motor without PWM] ok1hra | simple_rotator_interface_v [2026/09/27 09:19] (current) – [DC motor without PWM] ok1hra | ||
|---|---|---|---|
| Line 206: | Line 206: | ||
| - When using one turn of a **ten-turn potentiometer, | - When using one turn of a **ten-turn potentiometer, | ||
| - If you are using a **two-wire 500Ω potentiometer, | - If you are using a **two-wire 500Ω potentiometer, | ||
| + | |||
| + | | **Setup** Web page basic settings - [[# | ||
| + | | Azimuth potentiometer | **2 Wire** | | ||
| + | | Azimuth gain/shift op-amp | **OFF** | | ||
| ---- | ---- | ||
| Line 211: | Line 215: | ||
| ===== AC motor ===== | ===== AC motor ===== | ||
| {{https:// | {{https:// | ||
| + | |||
| + | | **Setup** Web page basic settings - [[# | ||
| + | | Hardware endstops | //depending on the rotator used// | | ||
| + | | Motor supply | **AC** | | ||
| + | **ATTENTION - the POE injector must be powered from another source than the source for AC motor!** | ||
| ---- | ---- | ||
| Line 221: | Line 230: | ||
| * Observe the **maximum prescribed loading.** | * Observe the **maximum prescribed loading.** | ||
| * We recommend using the **following safe option with software endstops.** | * We recommend using the **following safe option with software endstops.** | ||
| + | |||
| + | | **Setup** Web page basic settings - [[# | ||
| + | | Hardware endstops | //depending on the rotator used// | | ||
| + | | Motor supply | **DC** | | ||
| + | | DC PWM control | **ON** | | ||
| ---- | ---- | ||
| Line 231: | Line 245: | ||
| * observe the **polarity of the power supply,** otherwise the power mosfet may be destroyed. \\ | * observe the **polarity of the power supply,** otherwise the power mosfet may be destroyed. \\ | ||
| * observe the **maximum prescribed loading.** | * observe the **maximum prescribed loading.** | ||
| + | |||
| + | | **Setup** Web page basic settings - [[# | ||
| + | | Hardware endstops | **NOT INSTALLED** | | ||
| + | | Motor supply | **DC** | | ||
| + | | DC PWM control | **ON** | | ||
| Line 243: | Line 262: | ||
| - Don't forget to **bridge or replace the diode D24 with a jumper.** | - Don't forget to **bridge or replace the diode D24 with a jumper.** | ||
| - Make the **jumper with a copper wire** with a cross-section of 1.5 mm< | - Make the **jumper with a copper wire** with a cross-section of 1.5 mm< | ||
| + | |||
| + | | **Setup** Web page basic settings - [[# | ||
| + | | Hardware endstops | //depending on the rotator used// | | ||
| + | | Motor supply | **DC** | | ||
| + | | DC PWM control | **OFF** | | ||
| + | |||
| ---- | ---- | ||
| Line 248: | Line 273: | ||
| ===== Pulse Azimuth input ===== | ===== Pulse Azimuth input ===== | ||
| - | {{https:// | + | {{https:// |
| - | - TBD | + | Rotators that have a CW/CCW Pulse output as an azimuth sensor can be connected to the Jack connector (right). What is needed: |
| + | | ||
| + | * **connection** according to the picture {{https:// | ||
| + | * in the setup page in the **Sensors and limits** block set | ||
| + | * the **Azimuth source** to **CW/CCW Pulse** item | ||
| + | * the **Pulse count per degree** value | ||
| + | * then continue with the calibration page | ||
| + | |||
| + | **Schematic** of the input circuit \\ | ||
| + | {{https:// | ||
| ---- | ---- | ||
simple_rotator_interface_v.1779792016.txt.gz · Last modified: by ok1hra