REMOTIUS 64 - UNIVERSAL remote controller
This is IP controller designed for direct connection with our K9AY++ / 4-WAY and 7ANT controllers at first three banks or universal 12, 12, 13 and 16 outputs, one analog input (for 4SQ dummy load power), many temperature sensors for your PA, room, PS etc. This box offers web based User Interface, Beam Map control or any other system (NodeRed, StreamDeck etc.) Outputs including DC protection - electronic fuse. LAN port is 100 Mbit with double common-mode filter and high voltage protection. LED indications show status of the remote controller (each bank). There is also PTT hot switch protection when needed.
Main functions:
- Universal controller with 53 (total) outputs
- Each bank could have own User Interface
- Multi users control possible
- Web-based control with User Interfaces, Stream Deck, NodeRed etc.
- Bank 1: 12 outputs, directly designed for K9AY++/4-WAY or 7ANT
- Bank 2: 12 outputs, directly designed for 7ANT
- Bank 3: universal 13 OUT (also 7ANT, 6-to-2, beverage switch etc.)
- Bank 4: universal 16 OUT switching to ground
- Bank 1 nad 2 with PTT IN
- Bank 1 nad 2 with shared Analog IN (4SQ DL PWR)
- Bank 1 to 3 have positive voltage outputs - TBD example
- Bank 4 has negative voltage outputs - ULN example
- PTT hot switch protection built in (when needed)
- One PTT for ALL banks
- Up to 10 temperature sensors (18B20) example
- Easy to use with your own hardware
- Web based application with automated updates
- No configuration or firmware upload needed
- Custom button labels by parameter
- Customize your UI or use our control view
- Can be controlled by stream deck and touchportal
- System is part of our station automation infrastructure by DM5XX's RemoteSwitch.de system
- We recommend a VPN while using remote access from outside your network in general
- Easy configuration with EASY ASSISTANT
Parameters:
- Universal 53 outputs with + voltage or GND outputs (depends on bank) example
- Controller supply voltage 12 to 14V, max. 16 V DC / 1,5A, DC plug cable
- BANK 1 to 3 have positive drivers max. 26V DC
- BANK 4 is switching to Ground
- JUMPERS for different configuraton, pse see manual
- BANK 1 and 2 need EXT power supply max. 26V DC
- BANK 3 internal or EXT power supply controller voltage or EXT max. 26V DC
- BANK 4 could have 12 V output for external devices (relays), max. 0,5A
- BANK output current max. 500mA per output, 700mA total per bank
- Voltage drop for positive driver typ. 0,2V for +12V input and 0,7V including fuse
- Output voltage for positive driver is input voltage minus abt 0,7V
- BANK 4 voltage drop typ. 0,8V for +12V
- LED indication: ON BANK and PTT
- Temperature sensor: up to 10 of 18B20
- PTT IN: RCA or Bank 1 or 2
- PTT HOT switch protection for ALL banks
- PTT OUT: FET 0,5 A, 50V DC (no delay)
- Analog input: max. 16 V DC
- LAN 10/100 Mbit with filter and protection
- ONLY DHCP IP address - not static
BANKs summary:
- BANK 1: positive output needs external DC supply (max. 26V, 0,7A)
- BANK 2: positive output needs external DC supply (max. 26V, 0,7A)
- BANK 3: positive output supply from controller or Vext (pin 15), (max. 26V, 0,7A)
- BANK 4: negative output switching to ground (max. 50V, 0,5A per pin). Possible DC out for ext. device.
- BANK 4: possible DC out for ext. device Controller supply voltage, max. 0,5A
Analog input:
- One analog input for 4SQ UI
- Simply indication - low accuracy ADC
- Possible to use BANK 1 or 2 (shared one ADC)
- Internal 30 turn trimmer for scale set
- Full scale Voltage: min. typ. 4,2V, max. 16V DC
- Overdrive protection
Temperature sensor:
- Optional input designed for 18B20 sensors
- Star topology connection for more sensors
- You can use up to 10 pieces
- Sensor voltage 3V3
- Simply RFI filter
Technical articles:
- Introduction of our remote controlers At Technical Blog
- Remote K9AY++, 4-WAY beverage system and 7ANT At Technical Blog
Included in package:
- Controller assembled and tested
- DB25 male, 3psc DB15 female for your cable soldering
- DC plug cable connection
- Connector for 18B20 temperature sensors connecting
- Photo of included things
Optional:
- Optional temperature 18B20 sensors
- DB25 female, DB15 male with screw terminals at HamParts.shop
- DB25 female, DB15 male cable *** at HamParts.shop
Example for remote control User Interface (UI)
There can be up to 3 K9AY++ or 7ANT connected directly:
Related products:
OLI IP 16 universal remote controller |
OLI IP 12 K9AY++ / 7ANT remote controller |
Easy Controller for 1-3 stack match |
7ANT RX switch system |
K9AY++ remote |
Easy Controller 6-2 |